Flir A315 / A615




 FLIR A315FLIR A615
Imaging and optical data
Spatial resolution (IFOV)1.36 mrad0.69 mrad
Focal length18 mm24.5 mm
F-number1.31.0
Image frequency60 Hz50 Hz (100/200 Hz with windowing)
   
Detector data
IR resolution320 × 240 pixels640 × 480 pixels
Detector pitch25 μm17 μm
Detector time constantTypical 12 msTypical 8 ms
   
Measurement
Object temperature range–20 to +120°C 
0 to +350°C
-20 to +150°C
0 to +650°C 
+300 to +2000°C
   
USB
USBN/AControl and image
USB, standardN/AUSB 2 HS
USB, connector typeN/AUSB Mini-B
USB, communicationN/ATCP/IP socket-based FLIR proprietary
USB, image streamingN/A16-bit 640 × 480 pixels at 25 Hz
16-bit 640 × 240 pixels at 50 Hz
16-bit 640 × 120 pixels at 100 Hz
- Signal linear
- Temperature linear
- Radiometric
USB, protocolsN/ATCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
   
Ethernet
Ethernet, image streaming16-bit 320 × 240 pixels at 60 Hz
- Signal linear
- Temperature linear
- Radiometric
GigE Vision and GenICam compatible
16-bit 640 × 480 pixels at 50 Hz
16-bit 640 × 240 pixels at 100 Hz
16-bit 640 × 120 pixels at 200 Hz
- Signal linear
- Temperature linear
- Radiometric
GigE Vision and GenICam compatible

 

 FLIR A315 - StandardFLIR A315f - Environmental housingFLIR A615 - Standard
Environmental data
Operating temperature range–15°C to +50°C–25°C to +50°C–15°C to +50°C
EncapsulationIP 40 (IEC 60529)IP 66 (IEC 60529)IP 40 (IEC 60529)
Bump25 g (IEC 60068-2-29)5 g, 11 ms (IEC 60068-2-27)25 g (IEC 60068-2-29)
    
Physical data
Weight0.7 kg5 kg0.9 kg
Camera size (L × W × H)170 × 70 × 70 mm460 × 140 × 150 mm216 x 73 x 75 mm
Tripod mountingUNC ¼"-20 (on three sides)N/AUNC ¼"-20 (on three sides)
Base mounting2 × M4 thread mounting holes (on three sides)TBA2 × M4 thread mounting holes (on three sides)
    
System features
Automatic heatersN/AClears ice from windowN/A

General


Imaging and optical data
Field of view (FOV) / Minimum focus distance25° × 18.8° / 0.4 m
Lens identificationAutomatic
Thermal sensitivity/NETD< 0.05°C @ +30°C / 50 mK
FocusAutomatic or manual (built in motor)
  
Detector data
Focal Plane Array (FPA) / Spectral rangeUncooled microbolometer / 7.5–13 μm
  
Measurement
Accuracy±2°C or ±2% of reading
  
Measurement analysis
Atmospheric transmission correctionAutomatic, based on inputs for distance, atmospheric temperature and relative humidity
Optics transmission correctionAutomatic, based on signals from internal sensors
Emissivity correctionVariable from 0.01 to 1.0
Reflected apparent temperature correctionAutomatic, based on input of reflected temperature
External optics/windows correctionAutomatic, based on input of optics/window transmission and temperature
Measurement correctionsGlobal object parameters
  
Ethernet
EthernetControl and image
Ethernet, standardIEEE 802.3
Ethernet, connector typeRJ-45
Ethernet, typeGigabit Ethernet
Ethernet, communicationTCP/IP socket-based FLIR proprietary and GenICam protocol
Ethernet, protocolsTCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
  
Digital input/output
Digital input2 opto-isolated, 10–30 VDC
Digital output, purposeOutput to ext. device (programmatically set)
Digital output2 opto-isolated, 10–30 VDC, max 100 mA
Digital I/O, isolation voltage500 VRMS
Digital I/O, supply voltage12/24 VDC, max 200 mA
Digital I/O, connector type6-pole jackable screw terminal
Digital input, purposeImage tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
  
Power system
External power operation12/24 VDC, 24 W absolute max
External power, connector type2-pole jackable screw terminal
VoltageAllowed range 10–30 VDC
  
Digital input/output
Digital input, purposeImage tag (start, stop, general), Image flow ctrl. (Stream on/off), Input ext. device (programmatically read)
  
Environmental data
Storage temperature range–40°C to +70°C
Humidity (operating and storage)IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C
EMC• EN 61000-6-2:2001 (Immunity) 
• EN 61000-6-3:2001 (Emission) 
• FCC 47 CFR Part 15 Class B (Emission)
Vibration2 g (IEC 60068-2-6)
  
Physical data
Housing materialAluminium
  