Flir E6 / E8

FLIR Ex-Series: Technical specifications

Camera specific

 

FLIR E4

FLIR E5

FLIR E6

FLIR E8

IR resolution

80 x 60 pixels

120 x 90 pixels

160 x 120 pixels

320 x 240 pixels

MSX resolution

320 x 240 pixels

320 x 240 pixels

320 x 240 pixels

320 x 240 pixels

Thermal sensitivity

0.15°C

0.10°C

0.06°C

0.06°C

Spatial resolution (IFOV)

10.3 mrad

6.9 mrad

5.2 mrad

2.6 mrad

Image modes

IR image, visual image, MSX®, thumbnail gallery

IR image, visual image, MSX®, thumbnail gallery

IR image, visual image, MSX®, picture in picture, thumbnail gallery

IR image, visual image, MSX®, picture in picture, thumbnail gallery

Color alarm

NA

NA

Blue below or red above set temperature

Blue below or red above set temperature

 

General

Imaging performance

Field of view/min focus distance

45º x 34º / 0.5 m

Spectral range

7.5 - 13 µm

Image Frequency

9 Hz

Focus

Focus free

Focal Plane Array (FPA)

Uncooled microbolometer

 

Image Presentation

Display

3” 320 x 240 color LCD

Image adjustment

Automatic adjust/lock image

 

Measurement

Object temperature range

-20°C to +250°C

Accuracy

±2 °C or ±2% of reading , for ambient temperature 10°C to 35°C and object temperature above + 0°C

 

Measurement analysis

Spotmeter

Center spot

Emissivity correction

Variable from 0.1 to 1.0

Emissivity table

Emissivity table of predefined materials

Reflected apparent temperature correction

Automatic, based on input of reflected temperature

 

Setup

Color palettes

Iron, Rainbow and Black/White

Set-up commands

Local adaptation of units, language, date and time formats

 

Image Storage

Image storage capacity

Internal memory store at least 500 sets of images

Image storage mode

Simultaneous storage of images in IR, visual and MSX

File formats

Standard JPEG - 14 bit measurement data included

 

Data communication interfaces

Interfaces

USB Micro: Data transfer to and from PC and Mac device

 

Power system

Battery Type

Li-lon rechargeable

Battery voltage

3.7 V

Battery operating time

Approx. 4 hours at +25ºC ambient temperature and typical use

Charging system

Battery is charged inside the camera or in specific charger

Charging time

2.5 hours to 90% capacity in camera. 2 hours in charger

Power management

Automatic shutdown

AC operation

AC adapter, 90-260 VAC input, 5 VDC output to camera

 

Environmental specifications

Operating temperature range

-15°C to +50°C

Storage temperature range

-40°C to +70°C

Humidity

IEC 60068-2-30/24 h 95% relative humidity

EMC

Datasheet